Treatment plant bypass reported — Grand Island (T) SD#2 WWTP, Aug 3, 2026
Ended (as reported) · Grand Island (T) SD#2 WWTP (NY DEC Sewage Pollution Right to Know)
Source: Grand Island (T) SD#2 WWTP (NY DEC Sewage Pollution Right to Know), record 2657143257929669, reported Aug 3, 2026, 12:11 PM EDT, retrieved 2026-11-02 20:40 UTC · Read the original notice
Current status from this report
This report does not set a map status as of Nov 2, 2026, 4:26 PM EST. Check its dates and the status rules.
A report is not a test of the water. See how we assign statuses.
Read the original notice · Report an error
1. Reported wastewater outlet
Operator named in the record: Grand Island (T) SD#2 WWTP (federal wastewater discharge permit, NPDES, NY0027693). Outlet: “Haul truck hose failure.”. Location: 43.05700, -78.96790; location source: given in the source record.
Outfall: a pipe or outlet where wastewater enters a water body.
2. Waters named in the notice
The notice names: “Discharge did not enter waterways”. Not linked to a mapped water.
3. Estimated downstream stretch
We estimate routes only on rivers before they become tidal. We do not estimate routes through tidal water or lakes.
Map sources: water outlines and launches from OpenBoatLaunch and OpenStreetMap contributors (Open Database License); wastewater outlets from EPA and state records; downstream estimates by DirtyWaterWatch using U.S. Geological Survey maps and flow data. Base map: OpenFreeMap and OpenMapTiles.
When it happened and when it was reported
Event and notice times use Eastern Time (EST or EDT). Retrieval times use Coordinated Universal Time (UTC).
- Started
- Ended
- Detail provided by the source
- Times known to the minute
- Reported to the source
- Published
- Source last updated
- not given
- Last retrieved by DirtyWaterWatch
What and how much
- Type
- Treatment bypass: wastewater skips one or more treatment steps.
- Status in the record
- Ended (as reported)
- Material
- “Untreated”
- Volume
- 1,000 gallons (estimated)
- Volume as reported
- “Approximately 1,000 gallons Gallons Estimated”
Advice from Grand Island (T) SD#2 WWTP (NY DEC Sewage Pollution Right to Know)
This report includes no advice. Check current local health notices.
- Advice period
- This report does not state a period. See the rule DirtyWaterWatch applies and its source.
- Basis
- not stated
Source and versions
- Source
- NY DEC Sewage Pollution Right to Know
- Source record number
- 2657143257929669
- Original notice
- Read the original notice
- Earlier version
- None: this is the first record
- Later versions
- None
Record details
| Record identifier | ny-dec-sprtk:2657143257929669 |
|---|---|
| Source identifier | ny-dec-sprtk |
| Source record number | 2657143257929669 |
| Earlier version | Not provided |
| Type | Treatment plant bypass |
| Status in the report | Ended (as reported) |
| Sewer operator identifier | ny-grand-island-sd2 |
| Sewer operator | Grand Island (T) SD#2 WWTP |
| Federal wastewater discharge permit (NPDES) | NY0027693 |
| Outlet number | Not provided |
| Outlet name | Haul truck hose failure. |
| Water named in the report | Discharge did not enter waterways |
| Linked waters | Not provided |
| How this report was linked to the water | not linked to a mapped water |
| Latitude | 43.057 |
| Longitude | -78.968 |
| Location source | given in the source record |
| Location accuracy, in metres | Not provided |
| Started | Aug 3, 2026, 11:30 AM EDT (2026-08-03T11:30:00-04:00) |
| Ended | Aug 3, 2026, 11:35 AM EDT (2026-08-03T11:35:00-04:00) |
| Detail provided by the source | to the minute |
| Reported to the source | Aug 3, 2026, 12:11 PM EDT (2026-08-03T12:11:54-04:00) |
| Published | Aug 3, 2026, 12:11 PM EDT (2026-08-03T12:11:54-04:00) |
| Source last updated | Not provided |
| Last retrieved by DirtyWaterWatch | Nov 2, 2026, 3:40 PM EST (2026-11-02T20:40:35Z) |
| Material | Untreated |
| Volume, in gallons | 1,000 |
| Volume as reported | Approximately 1,000 gallons Gallons Estimated |
| How volume was determined | estimated |
| Authority | Grand Island (T) SD#2 WWTP (NY DEC Sewage Pollution Right to Know) |
| Advice | Not provided |
| Advice period, in hours | Not provided |
| Basis of the advice period | Not provided |
| Original notice | https://www.dec.ny.gov/fs/data/SPRTK_Data.xlsx |
Original source data
{
"row": {
"notificationId": "2657143257929669",
"sprtkAirDateTime": "08/03/2026 16:11:54",
"notificationStatus": "New",
"facilityName": "Grand Island (T) SD#2 WWTP",
"facilityId": "NY0027693",
"countyName": "Erie",
"streetNumber": "3500",
"streetName": "Baseline Road",
"city": "Grand Island",
"addressDescription": "Town of Grand Island WWTP",
"latitude": "-78.9679",
"longitude": "43.057",
"sprtkStartDischargeDatetime": "08/03/2026 15:30:00",
"sprtkEndDischargeDatetime": "08/03/2026 15:35:00",
"dischargeDuration": "Approximately 5 minutes Minutes - Ended",
"surfaceWater": "No",
"receivingWaterBody": "Discharge did not enter waterways.",
"componentDescription": "Haul truck hose failure.",
"quantity": "Approximately 1,000 gallons Gallons Estimated",
"treatedState": "Untreated",
"dischargeDescription": "Secondary digested sludge at less than 2% solids.",
"stepsToContain": "Spill socks deployed, spill was redirected to in-plant sanitary sewer manholes to reenter the system for treatment.",
"geoaddress": "3500 Baseline Rd, Grand Island, NY 14072, USA",
"impactedArea": "- Treatment plant parking lot.",
"dischargeReason": "Unknown - Haul truck hose failed allowing secondary digested sludge to spill onto the parking lot. Spill socks were deployed to protect storm sewer receivers, discharge redirected to the in-plant sewer.",
"systemComponent": "Other - Haul truck hose failure.",
"region": "9",
"sprtkDischargeWaterFlow": "Overland Flow",
"sprtkImpactAreaDesc": "Treatment plant parking lot.",
"sprtkExplanation": "Haul truck hose failed allowing secondary digested sludge to spill onto the parking lot. Spill socks were deployed to protect storm sewer receivers, discharge redirected to the in-plant sewer."
},
"_tab": "January 2026-August2026",
"_row": 4866,
"_time_basis": {
"air": "UTC in the workbook (rows aired from late May 2025); converted to America/New_York",
"start": "UTC in the workbook (rows aired from late May 2025); converted to America/New_York",
"end": "UTC in the workbook (rows aired from late May 2025); converted to America/New_York"
},
"_coords": "latitude and longitude columns swapped; a street-address geocode chosen by the notifier",
"_event_type_basis": "untreated discharge at the treatment plant (component or notice text)",
"_water": {
"why_none": "the notifier says the discharge does not reach surface water"
},
"_volume_note": "first (New) notice: NY-Alert requires a volume and an end time up front, so this figure is the notifier's estimate or placeholder, not a measured total",
"_chain": {
"id": "key:NY0027693|3500 baseline road grand island|2026-08-03T15:30Z",
"basis": "facility + address + start",
"position": 1,
"of": 1,
"head": "ny-dec-sprtk:2657143257929669",
"latest": "ny-dec-sprtk:2657143257929669",
"notices": [
{
"id": "2657143257929669",
"status": "New",
"aired": "2026-08-03T12:11:54-04:00"
}
]
}
} Source: Grand Island (T) SD#2 WWTP (NY DEC Sewage Pollution Right to Know), record 2657143257929669, reported Aug 3, 2026, 12:11 PM EDT, retrieved 2026-11-02 20:40 UTC · Read the original notice
Staff names, email addresses and phone numbers are removed from source data before it is stored.