DirtyWaterWatch Public waters. Public record.

Virginia / Reports /

Sanitary sewer overflow (SSO) reported, May 27, 2026

Ended (as reported) · Virginia DEQ Pollution Response Program (PReP), Valley Regional Office

Source: Virginia DEQ Pollution Response Program (PReP), Valley Regional Office via Virginia DEQ Pollution Response Program (PReP) pollution reports, sewage-related, record 323880, reported May 28, 2026, 12:00 AM EDT, retrieved 2026-11-03 02:40 UTC · Read the original notice

Current status from this report

This report does not set a map status as of Nov 2, 2026, 9:43 PM EST. Check its dates and the status rules.

A report is not a test of the water. See how we assign statuses.

Read the original notice · Report an error

1. Reported wastewater outlet

Operator named in the record: not named (federal wastewater discharge permit, NPDES, VA0027642). Outlet: not stated. Location: 39.31297, -78.30853; location source: geocoded from an address or place name.

Outfall: a pipe or outlet where wastewater enters a water body.

2. Waters named in the notice

The notice names no water. Not linked to a mapped water.

3. Estimated downstream stretch

We estimate routes only on rivers before they become tidal. We do not estimate routes through tidal water or lakes.

Map sources: water outlines and launches from OpenBoatLaunch and OpenStreetMap contributors (Open Database License); wastewater outlets from EPA and state records; downstream estimates by DirtyWaterWatch using U.S. Geological Survey maps and flow data. Base map: OpenFreeMap and OpenMapTiles.

Open on the main map

When it happened and when it was reported

Event and notice times use Eastern Time (EST or EDT). Retrieval times use Coordinated Universal Time (UTC).

Started
Ended
Detail provided by the source
Times known to the minute
Reported to the source
Published
not given
Source last updated
Last retrieved by DirtyWaterWatch

What and how much

Type
Sanitary sewer overflow (SSO): sewage spills from a sewer meant to carry sewage separately from rainwater.
Status in the record
Ended (as reported)
Material
“sewage”
Volume
307,000 gallons (not stated whether estimated or measured)
Volume as reported
“307,000 gallons”

Advice from Virginia DEQ Pollution Response Program (PReP), Valley Regional Office

This report includes no advice. Check current local health notices.

Advice period
This report does not state a period. See the rule DirtyWaterWatch applies and its source.
Basis
not stated

Source and versions

Source
Virginia DEQ Pollution Response Program (PReP) pollution reports, sewage-related
Source record number
323880
Original notice
Read the original notice
Earlier version
None: this is the first record
Later versions
None

Record details

Record details
Record identifierva-deq-prep:323880
Source identifierva-deq-prep
Source record number323880
Earlier versionNot provided
TypeSanitary sewer overflow (SSO)
Status in the reportEnded (as reported)
Sewer operator identifierNot provided
Sewer operatorNot provided
Federal wastewater discharge permit (NPDES)VA0027642
Outlet numberNot provided
Outlet nameNot provided
Water named in the reportNot provided
Linked watersNot provided
How this report was linked to the waternot linked to a mapped water
Latitude39.313
Longitude-78.309
Location sourcegeocoded from an address or place name
Location accuracy, in metresNot provided
StartedMay 27, 2026, 6:01 PM EDT (2026-05-27T18:01:00-04:00)
EndedMay 28, 2026, 12:01 PM EDT (2026-05-28T12:01:00-04:00)
Detail provided by the sourceto the minute
Reported to the sourceMay 28, 2026, 12:00 AM EDT (2026-05-28T00:00:00-04:00)
PublishedNot provided
Source last updatedJun 18, 2026, 1:09 PM EDT (2026-06-18T13:09:19-04:00)
Last retrieved by DirtyWaterWatchNov 2, 2026, 9:40 PM EST (2026-11-03T02:40:36Z)
Materialsewage
Volume, in gallons307,000
Volume as reported307,000 gallons
How volume was determinednot stated whether estimated or measured
AuthorityVirginia DEQ Pollution Response Program (PReP), Valley Regional Office
AdviceNot provided
Advice period, in hoursNot provided
Basis of the advice periodNot provided
Original noticehttps://portal.deq.virginia.gov/v2/prep/prepReport/323880

Original source data

{
  "report": {
    "id": "323880",
    "via": "api",
    "incident": "2026-05-27T18:01:00",
    "incident_end": null,
    "received": "2026-05-28T00:00:00",
    "closed": "2026-06-08T13:59:13",
    "modified": "2026-06-18T13:09:19",
    "date_unknown": false,
    "site_name": "Overflow-Aqua Virginia-Lake Holiday WWTP-South Lakeview Drive",
    "address": "231 South Lakeview Dr",
    "city": "Cross Junction",
    "zip": null,
    "county_city": "Frederick County",
    "region": "Valley",
    "status_text": "Closed",
    "categories": [
      "Sanitary Sewer Overflow"
    ],
    "waterbody": null,
    "other_waterbody": null,
    "original_waterbody": null,
    "water_threatened": "N",
    "low": null,
    "high": null,
    "unit": null,
    "ssors": null,
    "nrc": [],
    "vdem": null,
    "epa": null,
    "facility_name": "Lake Holiday WWTP",
    "facility_permitted": "Y",
    "responsible_company": "Aqua Virginia, Inc.",
    "still_occurring": "N"
  },
  "text": {
    "incident_comment": "Overflow at plant due to heavy rainfall I&I. Equalization basin was at max capacity so staff followed standard procedures for high flow conditions. The discharge lasted for 18 hours and approximately .307 MG flowed through the plant while aeration was off. Air supply was powered on to the activated sludge process and the plant returned to normal operation. Staff did not observe any fish kill or other obvious adverse impacts to the surrounding environment.",
    "location_comment": "231 South Lakeview Dr",
    "closure_comment": null
  },
  "sewage": [
    {
      "duration_h": 18,
      "component": null,
      "component_id": null,
      "volume_gal": 307000,
      "volume_unknown": null,
      "wet_weather": "Y",
      "treated": null,
      "precipitation_in": null,
      "causes": [
        "High Levels of Inflow and/or Infiltration"
      ],
      "impacts": [],
      "corrective_action": "Staff followed high flow procedures from the O&M manual.",
      "steps_taken": null,
      "component_comment": null,
      "other_cause": null
    }
  ],
  "status_log": [
    {
      "at": "2026-05-27T00:00:00",
      "type": "5-Day Letter"
    },
    {
      "at": "2026-06-08T13:53:18",
      "type": "Call Received"
    },
    {
      "at": "2026-06-08T13:53:27",
      "type": "Assigned"
    },
    {
      "at": "2026-06-08T13:53:27",
      "type": "Under Investigation"
    },
    {
      "at": "2026-06-08T13:59:13",
      "type": "Closed Call/IR"
    }
  ],
  "created_in_prep": "2026-06-08T13:53:18",
  "event_type_basis": "DEQ category Sanitary Sewer Overflow",
  "permit": {
    "typed_permit": "VA0027642",
    "deq_vpdes_links": [
      "VA0027642"
    ],
    "ms4": null,
    "ms4_links": null,
    "basis": "DEQ's VPDES link on the report"
  },
  "discharger_match": {
    "by_permit": null,
    "by_name": null
  },
  "volume_basis": "sewage report discharge volume (gallons)",
  "_ended_at_basis": "incident time + duration 18 h (sewage report)",
  "_time_basis": "PReP API times are local wall-clock times with no zone, read as America/New_York. The export table stores local time + 5 h all year (decoded by subtracting 5 h); the EDMA point layer stores local time labelled as UTC (decoded by reading the UTC clock as local).",
  "water_placement": {
    "text": null,
    "towns": [
      "Cross Junction",
      "Frederick County"
    ],
    "notes": null,
    "echo_outfall": null
  },
  "point": {
    "lat": 39.312969,
    "lon": -78.308527,
    "layer": "DEQ EDMA layer 175 (PReP Reports, Daily)",
    "reference_point": "PG",
    "note": "DEQ's geocode of the report's site address (REFERENCE_POINT 'PG'), not an outfall point",
    "edma_incident": "2026-05-27T18:01:00-04:00",
    "edma_received": "2026-05-28T00:00:00-04:00"
  },
  "attribution": "DEQ is the data source. DEQ does not certify that this data represents a complete record. This data is provided to the citizens of the Commonwealth free of charge and for informational purposes only.",
  "api_url": "https://portal.deq.virginia.gov/prep/api/prepReports/323880?expand=prepStatusCode,prepUnitTypeCode,prepReportSewages.prepComponentTypeCode,prepReportSewages.prepSewageCauses.prepCauseCode,prepReportSewages.prepSewageImpacts.prepImpactTypeCode,prepReportReleaseSubtypes.prepReleaseSubtypeCode,prepReportPermitViews,prepOriginalReport,prepReportEvents.prepEventTypeCode,prepFipsCode.fipsRegion"
}

Source: Virginia DEQ Pollution Response Program (PReP), Valley Regional Office via Virginia DEQ Pollution Response Program (PReP) pollution reports, sewage-related, record 323880, reported May 28, 2026, 12:00 AM EDT, retrieved 2026-11-03 02:40 UTC · Read the original notice

Staff names, email addresses and phone numbers are removed from source data before it is stored.