DirtyWaterWatch Public waters. Public record.

Florida / Reports /

Sanitary sewer overflow (SSO) reported — Miami-Dade Water & Sewer Collection System, Oct 12, 2026

Ended (as reported) · Florida Department of Environmental Protection (Public Notice of Pollution)

Source: Florida Department of Environmental Protection (Public Notice of Pollution) via Florida DEP Public Notice of Pollution, sewage and wastewater notices (PNP feature service), record 202610262-20261013T080043, reported Oct 13, 2026, 8:00 AM EDT, retrieved 2026-11-05 01:05 UTC · Read the original notice

Current status from this report

This report does not set a map status as of Nov 4, 2026, 8:25 PM EST. Check its dates and the status rules.

A report is not a test of the water. See how we assign statuses.

Read the original notice · Report an error

1. Reported wastewater outlet

Operator named in the record: Miami-Dade Water & Sewer Collection System. Outlet: “596185”. Location: 25.70096, -80.45519; location source: given in the source record, accurate to about 15 metres.

Outfall: a pipe or outlet where wastewater enters a water body.

2. Waters named in the notice

The notice names no water. Not linked to a mapped water. The report names no water and the operator lists 2 receiving waters (our list of sewer operators).

3. Estimated downstream stretch

We estimate routes only on rivers before they become tidal. We do not estimate routes through tidal water or lakes.

Map sources: water outlines and launches from OpenBoatLaunch and OpenStreetMap contributors (Open Database License); wastewater outlets from EPA and state records; downstream estimates by DirtyWaterWatch using U.S. Geological Survey maps and flow data. Base map: OpenFreeMap and OpenMapTiles.

Open on the main map

When it happened and when it was reported

Event and notice times use Eastern Time (EST or EDT). Retrieval times use Coordinated Universal Time (UTC).

Started
Ended
Detail provided by the source
Times known to the day only
Reported to the source
Published
not given
Source last updated
not given
Last retrieved by DirtyWaterWatch

What and how much

Type
Sanitary sewer overflow (SSO): sewage spills from a sewer meant to carry sewage separately from rainwater.
Status in the record
Ended (as reported)
Material
“untreated wastewater”
Volume
8,450 gallons (estimated)
Volume as reported
“8,450 gallons”

Advice from Florida Department of Environmental Protection (Public Notice of Pollution)

This report includes no advice. Check current local health notices.

Advice period
This report does not state a period. See the rule DirtyWaterWatch applies and its source.
Basis
not stated

Source and versions

Source
Florida DEP Public Notice of Pollution, sewage and wastewater notices (PNP feature service)
Source record number
202610262-20261013T080043
Original notice
Read the original notice
Earlier version
None: this is the first record
Later versions
None

Record details

Record details
Record identifierfl-dep-pnp:202610262-20261013T080043
Source identifierfl-dep-pnp
Source record number202610262-20261013T080043
Earlier versionNot provided
TypeSanitary sewer overflow (SSO)
Status in the reportEnded (as reported)
Sewer operator identifierfl-miami-dade-wasd
Sewer operatorMiami-Dade Water & Sewer Collection System
Federal wastewater discharge permit (NPDES)Not provided
Outlet numberNot provided
Outlet name596185
Water named in the reportNot provided
Linked watersNot provided
How this report was linked to the waternot linked to a mapped water
Latitude25.701
Longitude-80.455
Location sourcegiven in the source record
Location accuracy, in metres15
StartedOct 12, 2026 (2026-10-12T00:00:00-04:00)
EndedOct 12, 2026 (2026-10-12T00:00:00-04:00)
Detail provided by the sourceto the day only
Reported to the sourceOct 13, 2026 (2026-10-13T08:00:43-04:00)
PublishedNot provided
Source last updatedNot provided
Last retrieved by DirtyWaterWatchNov 4, 2026, 8:05 PM EST (2026-11-05T01:05:47Z)
Materialuntreated wastewater
Volume, in gallons8,450
Volume as reported8,450 gallons
How volume was determinedestimated
AuthorityFlorida Department of Environmental Protection (Public Notice of Pollution)
AdviceNot provided
Advice period, in hoursNot provided
Basis of the advice periodNot provided
Original noticehttps://ags.dep.state.fl.us/arcgis/rest/services/External_Services/PNP/FeatureServer/1/query?where=INCIDENT_NUMBER%3D202610262&outFields=INCIDENT_NUMBER,INCIDENT_NAME,INCIDENT_REPORT,DATE_TIME_OF_REPORT,RELEASE_START_DATE_TIME,RELEASE_ONGOING,RELEASE_END_DATE_TIME,FACILITY_NAME,FACILITY_ADDRESS_LINE_1,FACILITY_ADDRESS_LINE_2,FACILITY_CITY,FACILITY_STATE,FACILITY_ZIP5,AFFECTED_COUNTIES,MIGRATED_OFFSITE,MIGRATED_COUNTIES,LATITUDE,LONGITUDE,DATUM,MAP_SOURCE_SCALE,OBJECTID&returnGeometry=false&f=json

Original source data

{
  "INCIDENT_NUMBER": 202610262,
  "INCIDENT_NAME": "596185",
  "INCIDENT_REPORT": "DOMESTIC WASTEWATER DISCHARGE/ABNORMAL EVENT NOTIFICATION MIAMI-DADE COUNTY WATER AND SEWER DEPARTMENT EMERGENCY COMMUNICATIONS SECTION WASD Incident #: 596185 Version: 3 Version Type: Supplementary Incident Version Created On: 10/12/26 08:35 PM Job Order #: 1005554484 Location of Discharge: 6931 SW 162 CT UNINCORPORATED MIAMI-DADE 33193 Additional Location Description: 400 FT NORTH OF SW 78TH ST Reported by: [removed] Employee Title: PROJECT INSPECTOR [name removed] by: [removed] Utility Name: Miami-Dade Water & Sewer Phone Number: [removed] Path of Flow: South On: SW 162ND AVE Discharge Caused by Asset Type: Force Main Contractor Involved? No Discharge Due to/Caused by: Force Main Leaking Other Cause Is Severe Storm? No Additional Discharge Cause: BROKEN DUE TO IMPROPER BEDDING Pipe Material: DIP (Ductile Iron Pipe) Pipe Size in inches: 12 Type of Water Discharge: RAW SEWAGE Did Discharge Go to Public Access Area? Yes Did Discharge Go into Storm Sewer? Yes Number of Storm Drain(s) Impacted: 1 Distance in Feet to Storm Drain(s): 300 Direction: South Did Discharge Go into Surface Water? No Weather Conditions: Sunny Estimated Quantity of Sewage Released in Gallons: 8,450 Estimated Time Release Started: 10/12/26 10:39 AM Estimated Time Action Taken at Site: 10/12/26 11:30 AM ACTION TAKEN Active Spill Observed? Yes Discharge Flow Stopped? Yes Discharge Stopped On: 10/12/26 01:20 PM Spill Contained? Yes Area Cleaned? Yes Area Disinfected? Yes Method of Disinfection: Disinfectant/Vactor Public Notified: [removed] Method of Public Notification: Post Signs Public Notified On: 10/12/26 11:30 AM Spill Recovered? Yes Recovered Amount in Gallons: 6,600 AGENCIES NOTIFIED: [removed] Latitude: 25.7008191688889 Longitude: -80.4551068609581 10/12/26 08:57 PM * Fields on red are the ones that changed from previous version Page 1 of 2",
  "DATE_TIME_OF_REPORT": 1791878443000,
  "RELEASE_START_DATE_TIME": 1791763200000,
  "RELEASE_ONGOING": "N",
  "RELEASE_END_DATE_TIME": 1791763200000,
  "FACILITY_NAME": "Miami-Dade Water & Sewer Collection System",
  "FACILITY_ADDRESS_LINE_1": "6931 SW 162 CT",
  "FACILITY_ADDRESS_LINE_2": "20269340",
  "FACILITY_CITY": "Miami",
  "FACILITY_STATE": "FL",
  "FACILITY_ZIP5": 33193,
  "AFFECTED_COUNTIES": "Miami-Dade",
  "MIGRATED_OFFSITE": null,
  "MIGRATED_COUNTIES": null,
  "LATITUDE": 25.700956,
  "LONGITUDE": -80.455192,
  "DATUM": "WGS84",
  "MAP_SOURCE_SCALE": 4513
}

Staff names, email addresses and phone numbers are removed from source data before it is stored.